Weight:
The Single-Side Expandable weighs 2364
Kg (5200 pounds)
Payload:
6727 Kg (14,800 pounds)
Floor Load Center
Section:
522 Kg/m2 uniform load over the entire
floor (107 pounds/ft2)
Expandable Section:
910 Kg payload (2000 pounds)
Roof Load Center
Section:
366 Kg/m2 uniform load over the entire
roof (75 pounds/ft2)
Expandable Section:
195 Kg/m2 uniform load over the entire
roof (40 pounds /ft2)
Temperature Extremes
Operational: -54 C to 52 C
(-65 F to 125 F)
Non-Operational:
-62 C to 71 C
(-80 F to 160 F)
Wall
Attachment Loading:
Center Section: M8 Rivnuts installed in
members withstand 910 Kg (2000pounds)
tensile loads.
Expandable Section:
Potted Inserts installed anywhere withstand
455 Kg (1000 pounds) tensile loads.
Watertightness:
Double gaskets at all seams
for protection against wind-driven rain.
Optional Items:
Skids: Three full-length replaceable skids
Roof Access Steps:
Three recessed folding steps in sidewall
and one roof handhold
|
|
Military
Specifications:
MIL-M-81957(AS)
ISO/ANSI Specifications:
ISO 1496/1 and ANSI MH5.1.1.1 and 5.4
Exterior Dimensions:
96 in. high 96 in. wide, 238-1/2 in. long
Interior Dimensions:
84-5/16 in. high, 89 in. wide, 232
in. long
Shelter tare weight:
4,200 lbs.
Maximum Payload:
15,800 lbs.
Service Life:
15 years service, 20 years storage
Heat Transfer:
Insulated to provide a heat transfer coefficient
of 0.35 BTU/hr. ft 2/f
Temperature Range
Operation:
-40F to +125F plus solar load
to minimum of +180F
Storage:
-65F to +160F
Roof Loads:
Live load of 660 lbs. on an area 24 in.
by 12 in.; or 75lb. /ft2uniform snow load
Wall, Roof and Floor Attachments:
2,000 lb. pullout and 40 inch-lb. torque
|