NAVAIR
FEATURES & SPECIFICATIONS

Basic Mobile Facility Type B (BMFB)
This shelter is essentially the same as the Type A, but it is wired to operate on both 60 and 400 Hz power.

Side Opening Mobile Facility Type A (SOMFA)
This shelter is similar to the Basic Mobile Facility Type B except that it has provisions for two ECUs on one side and the other side is removable to permit complexing with either a Side Opening Mobile Facility Type B or a Side Opening Mobile Facility Type C.

Side Opening Mobile Facility Type B (SOMFB)
This shelter is similar to the Side Opening Mobile Facility Type A except that it has no end doors. It has a small personnel door located between the ECU opening on the non-removable side. This shelter is generally used in complexes with other side removable shelters.

Side Opening Mobile Facility Type C (SOMFC)
This shelter contains no power distribution or lighting, but it has two removable sides and a single end personnel door. It is generally used in complexes with other side removable shelters to provides increased workspace.

Integration Unit Mobile Facility (INU)
This shelter is used as a junction for up to 6 other MF units. It contains power distribution capabilities that allow it to transfer 200 Amp 60 Hz and 100 Amp 400 Hz power to the attached Mobile Facilities.

 

Military Specifications -
MIL-M-81957(AS)

ISO/ANSI Specifications -
ISO 1496/1 and ANSI MH5.1, 5.1.1 and 5.4

Exterior Dimensions -
96 in. high, 96 in. wide, 238 -1/2 in. long

Interior Dimensions -
84-5/16 in. high, 89-13/16 in. wide,
232-5/16 in. long

Shelter tare weight -
4,200 lbs.

Maximum Payload -
15,800 lbs.

Service Life -
15 years service, 20 years storage

Heat Transfer -
Insulated to provide a heat transfer coefficient of 0.25 BTU/hr. ft.2/°F

Temperature Range -
Operation: –40°F to +125°F plus solar load to minimum of +180°F. Storage –65°F to +160°F

Roof Loads -
Live load of 660 lbs. on an area 24 in. by 12 in.; or 75 lb./ft.2 uniform snow load

Wall, Roof and Floor Attachments -
2,000 lb. pullout and 40 inch-lb. torque


 

EXTERIOR
DIMENSIONS (1)

INTERIOR
DIMENSIONS
(2)
 

MODEL
NO.

DESCR
SPEC
H (in)
W (in)
L
(in)
H
(in)
W
(in)
L
(in)
SHELTER WEIGHT (LBS)

PAYLOAD
(LBS)

OUTLINE
DWG.
GMS-
628/1
Side
Opening
MF
(SOMF)-
Type A
MIL-M-
81957
96
96
238-
1/2
84-
5/16
89-
13/16
232-
5/16
4900
15.800
7006540
GMS-
628/2
Side Opening MF
(SOMF)-
Type B
MIL-M-
81957
96
96
238-
1/2
84-
5/16
89-
13/16
232-
5/16
4300
15.700
7006541
GMS-
11514
Side Opening MF
(SOMF)-
Type C
MIL-M-
81957
96
96
238-
1/2
84-
5/16
89-
13/16
232-
5/16
4300
15.700
1339AS1101
GMS-
11447
Side Opening MF
(SOMF)-
Double
Doors
MIL-M-
81957
96
96
238-
1/2
84-
5/16
89-
13/16
232-
5/16
4300
15.700
1339AS1100

Note: All shelters listed above are nominal 8’W x 8’H x 20’L, ISO shelters are also available in 10’, 30’ and 40’ lengths.

 